loader

DETERMINATION OF SEQUENCE IMPEDENCES OF THREE PHASE TRANSFORMER

Specifications:
  • This equipment should consists of Consist of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. With on board MCB, Power Indicators lamp, BTI-30 terminals, Voltmeter (0-500V-2no), Ammeter (0-5A-2no) 3 Ph. 2KVA, 400V/200 V Star-Delta Transformer 3Ph. @10A Auto Transformer Closed Type

DETERMINATION OF EQUIVALENT CIRCUIT OF THREE WINDING TRANSFORMER

Specifications:
  • This equipment should consists of Consists of a Panel Closed type with front Hylam sheet size 2ft ht x 4 ft wd x 200mm depth. with on board MCB, Power Indicators lamp ,BTI-30 terminals, Voltmeter(0-300V-2no), Ammeter(0-10A),UPF Wattmeter(500V/5A- 2nos), LPF Wattmeter(500V/5A-01 no) 3Ph, 3Winding 2.2KVA Transformer (P-400V in Star. S-200V in Star, T-80V in Delta.) 3Ph. @10A Auto Transformer Closed Type

DETERMINATION OF SEQUENCE IMPEDENCES OF CYLINDRICAL ROTOR SYNCHRONOUS MACHINE

Specifications:
  • This equipment should consists of Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. With on board MCB, Power Indicators lamp, BTI-30 terminals, fuse Protection, DC3 Point Starter, Voltmeter (500VAC), Voltmeter (300VDC), Ammeter (20ADC-2no), Ammeter (5AAC), 1Ph.Variac@6A, and Excitation Unit MACHINES:5HP DC Shunt Motor coupled to 3KW Alternator (Cylindrical Rotor Type,6 Terminal)

FAULT ANALYSIS OF A THREE PHASE ALTERNATOR (LG, LL, LLG, LLLG faults)

Specifications:
  • This equipment should consists of Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. With on board MCB, Power Indicators lamp, BTI-30 terminals, 3 Point Starter, Voltmeter (500V, AC), Voltmeter (300V, DC), Ammeter (20A, DC-2no), Ammeter (5A, AC) 1Ph.Variac@6A and Excitation Unit. MACHINES: 5HP DC Shunt motor coupled to 3KW Alternator (Cylindrical Rotor Type, 6 Terminals)

POWER ANGLE CHARACTERISTICS OF THREE PHASE ALTERNATOR

Specifications:
  • This equipment should consists of Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. With on board MCB, Power Indicators lamp, BTI-30 terminals, 3 Point Starter, Voltmeter (500V, AC), Voltmeter (300V, DC), Ammeter (20A, DC-2no), Ammeter (5A, AC) 1Ph.Variac@6A and Excitation Unit. MACHINES: 5HP DC Shunt motor coupled to 3KW Alternator (Cylindrical Rotor Type, 6 Terminals)

DETERMINATION OF SUB TRANSIENT REACTANCES OF A SYNCHRONOUS MACHINE

Specifications:
  • This equipment should consists of Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. with on board MCB, Power Indicators lamp, BTI-30 terminals, 3 Point Starter, Voltmeter (500VAC), Voltmeter (300VDC), Ammeter (20ADC-1no), Ammeter (5AAC), Phase sequence meter. 3Ph. @10A Auto Transformer Closed Type Rheostate-390Ω/1.2A MACHINES:5HP DC Shunt motor coupled to 3KW salient Pole Alternator

CHARACTERISTICS OF IDMT OVER CURRENT RELAY

Specifications:
  • This equipment should consists of Consists of a Panel Closed type with front Hylam sheet, Panel size 2ft ht x 4 ft wd x 200mm depth with on board MCB, Power Indicators Lamp, BTI-30 terminals, Electro Mechanical Type Relay- Alstom, 1Ph Variac@8A.Current Injecting Transformer@25A,Current controlling Choke@ 22A, Standard Class1 CT 20/5A, Ammeter (0-30A), CT-30/5A, Stopwatch, 4 Pole @16A Contactor with Push to ON and Push to OFF.

CHARACTERISTICS OF OVER VOLTAGE & UNDER VOLTAGE RELAY

Specifications:
  • This equipment should consists of Consists of a Panel Closed type with front Hylam sheet, Panel size 2ft ht x 4 ft wd x 200mm depth with on board MCB, Power Indicators Lamp, BTI-30 terminals, Microprocessor based Static UV/OV Relay (L&T), 1Ph.Variac@6A,Transformer-230V/320V@50mA, Voltmeter (0- 400VAC), Digital Stopwatch, 4 Pole@16AContactor with Push to ON and Push to OFF

CHARACTERISTICS OF STATIC NEGATIVE SEQUENCE RELAY

Specifications:
  • This equipment should consists of Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. with on board MCB, Power Indicators lamp, BTI-30 terminals, Static Negative Sequence Relay (ALSTOM ), 1Ph.Variac@8A-3nos, standard CT-5/5A-3nos,Voltmeter (0-500VAC-2no), Ammeter (0-10AAC -3nos), 3 Ph., 1.5KVA, 400V/100V- Delta/Star Transformer 3 Ph. Resistive Load Bank for Negative Sequence relay

CHARACTERISTICS OF PERCENTAGE BAISED DIFFERENTIAL RELAY

Specifications:
  • This equipment should consists of Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. with on board MCB, Power Indicators lamp, BTI-30 terminals, Standard CT-10/5A-3nos, Standard CT-5/5A- 3nos, 12Vto24V DC@5A, Ammeter (0-5A AC-7nos) , Voltmeter (0 -500VAC-2nos), 4 Pole@16AContactor with Push to ON and push to OFF contacts,% biased of Electro Magnetic differential Relay (Alstom). Differential relay consists of operating coil and restraining coil in Electro Magnetic Relay. The differential relay is adjustable 20%, 30% and 40%. 3Ph. @10A Auto Transformer Closed Type 3Ph. 3KVA, 400V/200V Star/ Star Transformer 3 Ph. Resistive Load Bank for % Biased Differential Sequence relay

DIFFERENTIAL PROTECTION OF SINGLE PHASE TRANSFORMER

Specifications:
  • This equipment should consists of Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth, with on board MCB, Power Indicators Lamp, BTI-30 terminals, Electro Mechanical Type Relay- Alstom, 1Ph. Variac@10, Standard CT 10/5A, Standard CT 10/5A, Voltmeter (0-500VAC-2nos), Ammeter (0- 20AAC-4nos). 1Ph. 2KVA, 230V/150V Transformer 1Ph. Resistive Load Bank for Differential Protection on 1Ph.Transformer relay

PERFORMANCE AND PROTECTION OF THREE PHASE TRANSFORMER

Specifications:
  • This equipment should consists of Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth,, with on board MCB, Power Indicators lamp, BTI-30 terminals, Over Current-2no, Earth Fault Relay-1no (Electro Mechanical type), Standard CT-10/2A- 3nos, Ammeter (0-5AAC-4nos), Voltmeter (0-500VAC-2no). Input supply will be taken from any one of the Alternators. 3 Ph. Resistive Load Bank for Generator/3Ph.Transformer Protection relay 3 Ph., 1.5KVA, 400V/100V Delta/Star Transformer 3Ph. @10A Auto Transformer Closed Type

PERFORMANCE AND TESTING OF THREE PHASE TRANSMISSION LINE

Specifications:
  • This equipment should consists of A) Determine Efficiency and Regulation of 3 phase Transmission Line model B) Fault analysis (LL,LG, LLL) of Transmission lines. C) Determination of ABCD Parameters of short, medium and long lines. Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 8 ft wd x 200mm depth. With on board MCB, Power Indicators Lamp, BTI-30 terminals, Inductor value: 0.006mH/km Capacitor value: 0 .025 mfd/ Km, Voltmeter (0-500VAC-2nos), Ammeter (0-10AAC-2nos), Wattmeter (500V/10A-4nos). LPF Wattmeter is required to conduct ABCD Parameters. 3Ph.@10A Auto Transformer Closed Type 3 Ph. @ 5A Resistive Load Bank, 6 steps

DETERMINATION OF LEAKAGE CURRENT OF PIN INSULATOR

Specifications:
  • This equipment should consists of Determination of leakage Current of Pin Insulator. Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm . High Voltage Protection and source unit 10KV

VOLTAGE DISTRIBUTION ACROSS STRING INSULATOR

Specifications:
  • This equipment should consists of Simulation of string of Insulators for determination of voltage distribution and string efficiency: Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm.A string of capacitances are mounted in the panel,1ph low voltage variac is mounted on the panel.