loader

CALIBRATION AND TESTING OF SINGLE PHASE ENERGY METER

Specifications:
  • This equipment should consists of Closed Box Type Hylam sheet Panel size 2ft ht x 4 ft wd with o board MCB, Power Indicators lamp, BTI-30 terminals, 1Ph.Energy Meter (1kw/h), Voltmeter (300V), Ammeter (10A), UPF Wattmeter (300V, 10A) and 1Ph Variac (270V/10A) Stop Watch ,Rheostart150W/5A

CALIBRATION OF DYNAMOMETER POWER FACTOR METER

Specifications:
  • This equipment should consists of Closed Box Type Hylam sheet. Panel size 2ft ht x 4 ft wd with on board MCB, Power Indicators lamp, BTI-30 terminals, Dynamometer power factor meter, LPF Wattmeter( 300V, 10A),Voltmeter (0-300V),Ammeter (0-10A), and 1Ph Variac (270V/10A). 1Ph. @10A Inductive load Close type ,Rheostart150W/5A

CALIBRATION OF LPF WATTMETER BY PHANTOM LOADING

Specifications:
  • This equipment should consists of Closed Box Type Hylam sheet. Panel size 2ft ht x 4 ft wd with on board MCB, Power Indicators lamp, BTI-30 terminals , LPF Wattmeter (300V, 10A), Voltmeter (0-300V), Ammeter (0-10A), and 1Ph Variac (270V/10A).Power factor meter 5A, 300V 1Ph. @10A Inductive load Close type ,Rheostart150W/5A

MEASUREMENT OF PARAMETERS OF A CHOKE COIL BY 3 VOLTMETER AND 3 AMMETER METHOD

Specifications:
  • This equipment should consists of Closed Box Type Hylam sheet. Panel size 2ft ht x 4 ft wd with on board MCB, Power Indicators lamp, BTI-30 terminals, Voltmeter (300V-3no), Ammeter (10A-3no), and 1Ph Variac (270V/10A). Chock Coil@5A,Rheostate150Ohms/5A

MEASUREMENT OF 3 PH POWER WITH SINGLE WATTMETER AND 2 No CT

Specifications:
  • This equipment should consists of Closed Box Type Hylam sheet. Panel size 2ft ht x 4 ft wd with on board MCB, Power Indicators lamp, BTI-30 terminals, Voltmeter (0-600V), Ammeter (0-10A), UPF Wattmeter (500V, 10A), Current Transformer (5/10/15/20A-2no) 3Ph. @10A Auto Transformer Closed Type 3 Ph. @ 5A Resistive Load Bank, 6 steps

MEASUREMENT OF 3 PH POWER WITH TWO WATTMETERS FOR BALANCED/UNBALANCED LOAD

Specifications:
  • This equipment should consists of Closed Box Type Hylam sheet. Panel size 2ft ht x 4 ft wd with on board MCB, Power Indicators lamp, BTI-30 terminals, Voltmeter (0-500V), Ammeter (0-10A), UPF Wattmeter (500V, 10A-2no). 3Ph. @10A Auto Transformer Closed Type 3Ph.@5A Resistive Load Bank- Balanced & Unbalanced for Two watt meter Method

MEASUREMENT OF 3 PH ACTIVE POWER FOR STAR/DELTA CONNECTED LOAD

Specifications:
  • This equipment should consists of Closed Box Type Hylam sheet. Panel size 2ft ht x 4 ft wd with on board MCB , Power Indicators lamp, BTI-30 terminals, Voltmeter (0-500V), Ammeter (0-10A), UPF Wattmeter (500V, 10A) 3Ph. @10A Auto Transformer Closed Type 3 Ph.@ 5A Resistive Load Bank,6 steps

MEASUREMENT OF 3 PH REACTIVE POWER FOR STAR/DELTA CONNECTED LOAD

Specifications:
  • This equipment should consists of Closed Box Type Hylam sheet. Panel size 2ft ht x 4 ft wd with on board MCB , Power Indicators lamp, BTI-30 terminals, Voltmeter (0-500V), Ammeter (0-10A), LPF Wattmeter (500V, 10A) 3Ph. @10A Auto Transformer Closed Type 3 Ph. @ 5A inductive Load Bank, 4 steps

MEASUREMENT OF 3 PH REACTIVE POWER WITH SINGLE WATTMETER

Specifications:
  • This equipment should consists of Closed Box Type Hylam sheet. Panel size 2ft ht x 4 ft wd with on board MCB, Power Indicators lamp, BTI-30 terminals, Voltmeter (500V), Ammeter (10A), LPF Wattmeter (500V/10A). 3Ph. @10A Auto Transformer Closed Type 3 Ph. @ 5A inductive Load Bank, 4 steps

CT TESTING BY COMPARISION METHOD(SILSEBE’S TESTING)

Specifications:
  • This equipment should consists of Closed Box Type Hylam sheet. Panel size 2ft ht x 4 ft wd with on board MCB, Power Indicators lamp, BTI-30 terminals, Voltmeter (0-500V), Ammeter (5A-2no), UPF Wattmeter (600W,3A,250V-2no),Current Transformer (5/10/15/20A-2no) and 1Ph Variac (270V/10A). Rheostat 150Ohms/5A-02 3Ph. 500VA, Phase Shifting Transformer

PT TESTING BY COMPARISION METHOD

Specifications:
  • This equipment should consists of Closed Box Type Hylam sheet. Panel size 2ft ht x 4 ft wd with on board MCB, Power Indicators lamp,BTI-30 terminals, Voltmeter(0-500V-02no),Ammeter (5A-1no),UPF Wattmeter (600W, 3A, 250V-2no), potential Transformer (440/115-2no) and 1Ph Variac (270V/10A). Rheostat 150Ohms/5A-02 3Ph. 500VA, Phase Shifting Transformer

CT & PT TESTING BY COMPARISION METHOD

Specifications:
  • This equipment should consists of Closed Box Type Hylam sheet. Panel size 2ft ht x 4 ft wd with on board MCB, Power Indicators lamp,BTI-30 terminals, Voltmeter(0-500V-2no),Ammeter (5A-2no), UPF Wattmeter (600W, 3A, 250V-2no), Current Transformer (5/10/15/20A-2no), Potential Transformer (415/110v-2no) 1Ph Variac (270V/10A). Rheostat 150Ohms/5A-02 3Ph. 500VA, Phase Shifting Transformer

CT TESTING BY MUTUAL INDUCTANCE (NULL METHOD)

Specifications:
  • This equipment should consists of a) CT Test Bridge (5A OR 1A Sec) b) AC Null Detector For above c) Spot Vibration galvano Meter Optional equipment 1 ph variac (0-270)V Rheostat 150ohm/5A

PT TESTING BY MUTUAL INDUCTANCE (NULL METHOD)

Specifications:
  • This equipment should consists of a) PT Test Bridge ( 115vSec) b) AC Null Detector For above c) Spot Vibration galvano Meter Optional equipment 1 ph variac (0-270)V

CROMPTON DC POTENTIO METER

Specifications:
  • This equipment should consists of A) Crompton DC Potentiometers (Measuring from DC 500mV to 1.75V) Electronic Standard Cell -1.0180V 2V Fixed Power Supply (Chemical Battery) Volt Ratio Box Galvanometer

ANDERSON’S BRIDGE(INDUCTANCE MEASUREMENT)

Specifications:
  • This equipment should consists of A) Anderson bridge 1 KHz A.F. Oscillator Unknown Inductor Pair of head phones

SCHERING BRIDGE (CAPACITANCE MEASUREMENT)

Specifications:
  • This equipment should consists of A) Schering bridge including 1 KHz A.F. Oscillator, Unknown capacitance Pair of head phones

WHEAT STONE BRIDGE

Specifications:
  • This equipment should consists of A) Wheat Stone Bridge with galvanometer and battery with necessary equipment

MAXWELL BRIDGE

Specifications:
  • This equipment should consists of A) Maxwell Bridge with all Necessary accessories

KELVIN DOUBLE BRIDGE

Specifications:
  • This control panel consists of
  • This equipment should consists of Measurement of Resistance-Determination of Tolerance. Kelvin double bridge with 0.1W, 5Amp and 1W, 3Amp resistance Standard resistance:1Ω/3A Standard resistance:0.1Ω/5A

WEIN BRIDGE

Specifications:
  • This equipment should consists of Maxwell Bridge with all Necessary accessories

DIELECTRIC OIL TESTING USING HT TESTING KIT

Specifications:
  • This equipment should consists of HT testing equipment of 60 KV Highly Insulated fiber box with two electrodes are provided. On and OFF push buttons to operate the equipment 1 ph variac to vary the KV from 0 to 60 KV

TRANSFORMER TURNS RATIO KIT

Specifications:
  • This equipment should consists of Complete bridge to find the turn ratio of the given transformer One galvanometer is provided. Selector switches for different ranges are given internally.