Analog Multitester YX-360

 

  SPECIFICATION:  
  DC VOLTAGE:  
  Ranges: 0.1-0.5-2.5-10-50-250100V
  Accuracy at FSD : 3 ;( 1000V; 5)
  Sensitivity : 20KΩ/V
  Extension  : 25KV (With HV Probe Extra)
  AC VOLTAGE  
  Ranges: 10-50-250-1000V
  Accuracy at FSD : 4; 1000V; 5
  Sensitivity : 9KΩ/V
  Decibel meter    :-10 to +23dB
    OdB=1mw/600Ω
  DC CURRENT  
  Ranges: 50µA (at 0.1 VDC Position), 2.5mA, 25mA:0.25A,*10A
  Accuracy at FSD   : 3(10A;5)
  Volte Drop : 250mV
  RESISTANCE  
  Ranges X1-0.2Ω up  to 2kΩ, Midscale, at20Ω
X10-2Ω up to 20KΩ, Midscale, at 200Ω
** X100-20Ω up to 200KΩ, Midscale, at 2kΩ
X1K-200Ω up to 2MΩ, Midscale, at 20KΩ
X10K-2KΩ up to 20MΩ, Midscale, at 200KΩ
  Accuracy at /fsd: 3    Iceo 150 µA-15mA-150mA
hFE 0-1000(With Connector Extra)
Size 148X100X35
  Weight 280g DCA Range for #YX-360 TRN-A
** Ω Range for #YX-360 TRE; #YX-360 TRE-B
#YX-360 TRE-B-L
     
 

Multimeter Digital - (Model : DM-97 )

Characteristics:
1
. GENERAL,1.LCD displaylaying

  • 1.2. Max. displaying. 1999(3 ½ digit)auto polarity indication.
  • 1.3. Measuring method: dual slope A/D conversion.
  • 1.4. Operation uninterrrruptable purpose.
  • 1.5. Using Panel testing technology.
  • 1.6. Sampling rate : approx. 3times/second.
  • 1.7. Over range indication: the MSD displays “OL”.
  • 1.8. Low battery indication + + appears.
  • .9. Operation environment (0~40) ºC, r.h. <80%.
  • 1.10. Power : 9Vx1 (NEDA1604/6F22 or equivalent model),
  • 1.11. Size : 175x93x55mm.
  • 1.12. Weight approx, 400g (Including battery).
  • 1.13. Accessories: Operation manual, hoister, gift box, 10A test leads and 9V battery.
 
  2.  TECHNICAL CHARACTERISTIC  
     
  2.1. Accuracy : ±(a% x rdg+d) at (23±5) °C, R,H, <75%, one year guaranteed from the production date. 2.2. TECHNICAL DATA
 

RANGE

ACCURACY

RESOLUTION

200mV

±(0-5%+3)

100μV

2V

 

1mV

2V

1mV

20V

10mV

200V

100mV

1000V

±(0.8%+10)

1V

Input resistance: 5m Ω at mV range, other range : 10mΩ
Overload protection: 250V dV  or AV peak value at 200m V range.
1000V DC or AC peak value at other ranges.
     
  2-2-2. ACV 2-2-3. DCA
 
RANGE

ACCURACY

RESOLUTION

2V

 

±(0.8%+5)

1mV

20V

10mV

200V

100mV

750V

±(1.2%+10)

1V

RANGE

ACCURACY

RESOLUTION

20μA

 

±(0.8%+10)

0.1μA

2mA

1μA

20mA

10μA

200mA

±(1.2%+8)

100μA

20A

±(1.2%+5)

10mA

  Input resistance 10 M Ω
Overload protection: 1000V DC or AC peak value
Frequency response: (10~200) Hz
Display: Sine wave RMS (mean value response)
Max. Input volt drop: 200mV:
Max. Input current: 20A (the test time should ebe within 10 seconds)
Overload protection: 0.2A/250V fast-melt flues
     
  2-2-4. ACA 2-2-25. RESISTANCE (Ω)
 
RANGE

ACCURACY

RESOLUTION

20mA

±(1.0%+15)

10 μA

200mA

±(2.0%+5)

100μA

20A

±(3.0%+10)

10mA

Max. Measuring volt drop : 200mV
Max. Input current 20A (the test time should be within 10 seconds)
Overload protection: 0.2A/250V: 20A/250V fast-blown fuse
Frequency response: (40-200)Hz
Display: Sine wave RMS (mean value response)

RANGE

ACCURACY

RESOLUTION

200Ω

±(0.8%+5)

0.1Ω

2K Ω

 

1Ω

20KΩ

10Ω

200KΩ

±(0.8%+3)

100Ω

2MΩ

1KΩ

20MΩ

±(1.0%+25)

10KΩ

     
  2-2-7. DIODE AND CONTINUITY TEST 2-2-8. Triode hFE test
 
Range

Displaying Value

Test condition

 

Positive Voltage drop of diode

The Positive DC current is approx.  1mA, negative voltage is approx. 3V

Buzzer sounds, the resistance is less than 30 Ω

Open voltage is approx. 3V

Range

Display range

Test condition

hFE NPN or PNP

0~1000

Basic current is approx. 10μA, Vce is
Approx 3V

     
  Overload protection: 250V DC or AC peak value  
  Warning : DO NOT input any voltage at this range for safety  
  Open Voltage: less than 0.7V
Overload Protection : 250V DC and AC peak value
NOTE : at 200 Ω range, the leads should be short-circuit, and measure the down-lead resistance, then, subtract from the real measuring.
2-2-6. CAPACITANCE (c).
 
 
RANGE

ACCURACY

RESOLUTION

2nF

±(5.0%+40)

1pF

20nF

 

±(2.5%+20)

10pF

2-200μF

1-100nF

2000 μF

±(5.0%+10)

1μF

Overload Protection : 36V