loader

 

DUAL CHANNEL REGULATED POWER SUPPLY-SRPS-301D/SRPS-302D

       Features:
     óSleek & Compact

      ó Low Noise & Ripple
 
      ó Good Line & Load Regulation  
    ó Short Circuit & Fold Back protection

     ó  Digital Display

     ó Custom Built Supplies

       Technical Specifications:

     Input                           :   230V  +/- 10% AC,50HZ

    output                         :    0-30V DC, Continuously Variable with fine and coarse 
                                             Variation

    Out Put Current          : 0-1/2 Amp, Continuously  Variable
                                          Constant  Voltage Mode: When the load current is less the
                                          Current limit set by current Control. When the load current 
                                           limit 

    Mode of  operation      : Requirement is more than the current limit set by current
                                           Control automatic switch over from constant voltage mode
                                           To  Constant current mode takes place  

    Load Regulation         : +/-0.01% from on load to full load

    Line Regulation          : +/-0.01% for +/-10% Variation input line voltage.

    Ripple Voltage            : Less than 1 mV rms

    Meters                         : Two digital meters provided to measure voltage and current    
                                          With Switch Selection

    Meter Accuracy          : +/-0.2% of reading,+/-2 least Counts

    Protection                   : Continuous overload and short circuit Protection

      -----------------------------------------------------------------------------------------------------------------------------------------------

            


SINGLE  CHANNEL REGULATED POWER SUPPLY-SRPS-301/302

    Features:
     óSleek & Compact                                                                     

      ó Low Noise & Ripple
 
      ó Good Line & Load Regulation  

     ó Short Circuit & Fold Back protection

     ó  Digital Display

     ó Custom Built Supplies

       Technical Specifications:

     Input                           :   230V  +/- 10% AC,50HZ

    output                         :    0-30V DC, Continuously Variable with fine and coarse 
                                             Variation

    Out Put Current          : 0-1/2 Amp, Continuously  Variable
                                          Constant  Voltage Mode: When the load current is less the
                                          Current limit set by current Control. When the load current 
                                           limit 

   Mode of  operation      : Requirement is more than the current limit set by current
                                           Control automatic switch over from constant voltage mode
                                           To  Constant current mode takes place  

    Load Regulation         : +/-0.01% from on load to full load

    Line Regulation          : +/-0.01% for +/-10% Variation input line voltage.

    Ripple Voltage            : Less than 1 mV rms

    Meters                         : Two digital meters provided to measure voltage and current    
                                          With Switch Selection

    Meter Accuracy          : +/-0.2% of reading,+/-2 least Counts

    Protection                   : Continuous overload and short circuit Protection

 

   ---------------------------------------------------------------------------------------------------------------------------------------------------
      
    


DUAL CHANNEL REGULATED POWER SUPPLY-SRPS-301D/SRPS-302D

  

       Features:
     óSleek & Compact

      ó Low Noise & Ripple
 
      ó Good Line & Load Regulation  
   
    ó Short Circuit & Fold Back protection

     ó  Analog  Display

     ó Custom Built Supplies

       Technical Specifications:

     Input                           :   230V  +/- 10% AC,50HZ

    output                         :    0-30V DC, Continuously Variable with fine and coarse 
                                             Variation

    Out Put Current          : 0-1/2 Amp, Continuously  Variable
                                          Constant  Voltage Mode: When the load current is less the
                                          Current limit set by current Control. When the load current 
                                           limit 

    Mode of  operation      : Requirement is more than the current limit set by current
                                           Control automatic switch over from constant voltage mode
                                           To  Constant current mode takes place  

    Load Regulation         : +/-0.01% from on load to full load

    Line Regulation          : +/-0.01% for +/-10% Variation input line voltage.

    Ripple Voltage            : Less than 1 mV rms

    Meters                         : Two Analog  meters provided to measure voltage and current    
                                          With Switch Selection

    Meter Accuracy          : +/-0.2% of reading,+/-2 least Counts

    Protection                   : Continuous overload and short circuit Protection

     


DUAL CHANNEL REGULATED POWER SUPPLY-SRPS-301D/SRPS-302D

  

       Features:
     óSleek & Compact

      ó Low Noise & Ripple
 
      ó Good Line & Load Regulation  
   
    ó Short Circuit & Fold Back protection

      ó  Digital  Display

      ó Custom Built Supplies

       Technical Specifications:

     Input                           :   230V  +/- 10% AC,50HZ

    output                         :    0-30V DC, Continuously Variable with fine and coarse 
                                             Variation

    Out Put Current          : 0-1/2 Amp, Continuously  Variable
                                          Constant  Voltage Mode: When the load current is less the
                                          Current limit set by current Control. When the load current 
                                           limit 

    Mode of  operation      : Requirement is more than the current limit set by current
                                           Control automatic switch over from constant voltage mode
                                           To  Constant current mode takes place  

    Load Regulation         : +/-0.01% from on load to full load

    Line Regulation          : +/-0.01% for +/-10% Variation input line voltage.

    Ripple Voltage            : Less than 1 mV rms

    Meters                         : Four Digital meters provided to measure voltage and current    
                                          With Switch Selection

    Meter Accuracy          : +/-0.2% of reading,+/-2 least Counts

    Protection                   : Continuous overload and short circuit Protection

 

SINGLE  CHANNEL REGULATED POWER SUPPLY-SRPS- 0-5V

    


    Features:
     óSleek & Compact                                                                     

      ó Low Noise & Ripple
 
      ó Good Line & Load Regulation  

     ó Short Circuit & Fold Back protection

       ó Custom Built Supplies

  Technical Specifications:

     Input                           :   230V  +/- 10% AC,50HZ

    output                         :    0-5V DC, Continuously Variable with fine and coarse 
                                             Variation

    Out Put Current          : 0-500mA /1 Amp, Continuously  Variable
                                          Constant  Voltage Mode: When the load current is less the
                                          Current limit set by current Control. When the load current 
                                           limit 

   Mode of  operation      : Requirement is more than the current limit set by current
                                           Control automatic switch over from constant voltage mode
                                           To  Constant current mode takes place  

    Load Regulation         : +/-0.01% from on load to full load

    Line Regulation          : +/-0.01% for +/-10% Variation input line voltage.

    Ripple Voltage            : Less than 5 mV rms

     Meter Accuracy          : +/-0.2% of reading,+/-2 least Counts

    _________________________________________________________________________________________________

FIXED REGULATED POWER SUPPLY-SRPS-15V/12V/5V

 

    Features:
     óSleek & Compact                                                                     

      ó Low Noise & Ripple
 
      ó Good Line & Load Regulation  

     ó Short Circuit & Fold Back protection

     ó Custom Built Supplies

    Technical Specifications:

     Input                           :   230V  +/- 10% AC,50HZ

    output                         :    +/- 15V/12V/5V

    Out Put Current          : 250mA/ 500mA  
                                         
   Mode of  operation      : Requirement is more than the current limit set by current
                                           Control automatic switch over from constant voltage mode
                                           To  Constant current mode takes place  

    Load Regulation         : +/-0.01% from on load to full load

    Line Regulation          : +/-0.01% for +/-10% Variation input line voltage.

    Ripple Voltage            : Less than 5 mV rms

     Meter Accuracy          : +/-0.2% of reading,+/-2 least Counts

    Protection                   : Continuous overload and short circuit Protection